GGC8-3-IND-UL 8-3 GGC 2KV INTEGRAL FILL UL廈門緯軒機電設備有限公司座落于環境優美的廈門市區.公司以國內制造產業升級為契機,著眼于現代化的自動化工業生產裝備產業.以經營代理國內外知名DCS系統備件及工業自動化元件產品為主,以承接自動化項目軟/硬件研發設計,安裝調試,項目改造,元件技術服務為輔.真誠為奮斗在自動化工業發展進程中的每一位同仁服務.通過公司銷售與工程技術人員的真誠服務與不懈努力. 秉承”誠信經營互惠互利”的經營宗旨.成功為國內自動化貿易商,鋼鐵,電力,有色金屬,汽車制造等行業企業提供產品供應及技術支持服務.并贏得廣大客戶的青睞! 歡迎各界朋友來電來函咨詢公司產品及服務,我們將為您提供最周全的售前,售中,售后服務.實現彼此共贏!QQ3157966191
"Versa
" VGG-4422-U-A240
P-1002-02-A240 KRAL DS1/1000.21X
Turck 1440005 Part No.: NI40R-S32SR-VP44X
RNID-RSI-0141 ALCAD XHP80 CELLS
博格曼Burgmann MG1/90-G6-Q1Q1PGG
ASCO阿斯卡 電磁閥,型號:NO:YA2BB-4520G000-40??OPER.PRESSURE(AIR):14.5-145?PSIG(1-10BAR)?220V,
KRAL DS1/1000.21X
XJLD N4 XJTD N4 XJHAD N4 XJHAD N4
Without cover to show opUJPOBMNPVOUJOHCSBDLFU
XJHCD N4
XJKD N4 XJKAD N4 XJWT N4 XJWT_N4 XJSD N4
XJWH N4 XJW N4
To house transfer switch
modification
(Not UL or CSA)
r %JNFOTJPOTBSFOPNJOBMJOUFSOBMBOEMJTUFEPOUIFGPMMPXJOHQBHFT
41 The ADALET Engineering Department is Available to Assist you in the Selection of Enclosures and Accessories.
Junction Boxes
EXPLOSIONPROOF
UL 886
CSA C22.2 No. 25 & 30
UL 50
CERTIFICATIONS
Class I, Groups C,D
Class II, Groups E,F,G
TYPE 4
Explosionproof Meter Housings
-Dome Cover
288 The ADALET Engineering Department is Available to Assist you in the Selection of Enclosures and Accessories.
EXPLOSIONPROOF METER HOUSINGS
DOME COVER
A
5 ?
6 9?16
6 11?16
7
8 3?8
B
6
6
7
7 7?16
5 13?16
6
A B
7 ?
Explosionproof Meter Housings
-Dome Cover
XJLD_ N4
XJTD_ N4
NOMINAL DIMENSIONS
Max Box Inside Dimensions Inside Overall Dia. Mounting Weight
Catalog Conduit Dome Height Cover Hole Each
# Size WLD A B Opening Size Pounds
XJLD4 N4 2 6 6 3 ? 8 9?16 9 13?16 5 3?8 7?16 12
XJLD6 N4 2 6 6 3 ? 9 7?8 11 1?8 5 3?8 7?16 13
XJLD10 N4 2 6 6 3 ? 14 3?8 15 5?8 5 3?8 7?16 15
XJLD13 N4 2 6 6 3 ? 17 3?8 18 5?8 5 3?8 7?16 16
XJTD4 N4 2 5 13?16 6 9?16 4 9 10 ? 5 3?8 ? 13 ?
XJTD6 N4 2 5 13?16 6 9?16 4 10 3?8 11 5?8 5 3?8 ? 14 ?
XJTD10 N4 2 5 13?16 6 9?16 4 14 7?8 16 1?8 5 3?8 ? 16 ?
XJTD13 N4 2 5 13?16 6 9?16 4 17 7?8 19 1?8 5 3?8 ? 17 ?
STANDARD FEATURES
r5IJTHSPVQPGIPVTJOHTJTEFTJHOFEGPSFODMPTJOHSFMBZT contactors and terminal strips. They are also suitable for ac
commodating splices of heavy conductors
r8IFOVTFEGPSTQMJDJOH
UIFDPOEVDUPSTNBZCFQVMMFEJOXJUI
UIFFOETFYUFOEJOHPVUCFZPOEUIFDPWFSPQFOJOH
NBLJOH
them accessible for splicing. When splices are completed, they
OFFEOPUCFDSPXEFECBDLJOUPUIFCPEZCVUDBOCFQSPUFDUFE
with the dome cover assembled to the housing.
r 0QUJPOBMNPVOUJOHQBOTBWBJMBCMFDPOTVMUGBDUPSZ
4801 West 150th Street, Cleveland, Ohio 44135 TEL 216.267.9000 FAX 216.267.1681 info@adalet.com 42EXPLOSIONPROOF
Junction BoxesLubrimat? L60
Page 8
System components:
1. Base / Base addition
- Pneumatically driven, finely meterable piston pump with FPM seals, manually
adjustable with PMC precise metering control , enabling easy adjustment of the
volume using a dial. Volume 0 - 0.03 ml per stroke. If required, pumps with double flow
volume (2DF) with up to 0.06 ml per stroke are available.
- All pumps are standard synchronous drive. Separate drive, if required (all
pumps individually or certain groups). The use of the logic panel enables all
pumps to be operated using only one frequency generator.
- Ventilation unit integrated underneath the pump module.
- Frequency generator for pump pulses, manually adjustable 0 - 90 stroke min-1.
- A dedicated air valve for each nozzle, to enable the quantity of spray air to
be adjusted.
- Pressure reducing valve to set spray air pressure. It also equalizes
pressure variations in the supply tube and the system and ensures that the
spray profile is even.
- Manometer (0 – 10 bar) in front of door to display spray air pressure.
- Coupler plug for compressed air supply to left side of housing.
- Air filter with integrated water separator and drainage opening on housing
underside.
- High-grade push in/screw fittings/ pneumatic tubes.
- Stable, compact metal housing (200x200x155, 250x250x210, 300x250x210, or 400x400x210) with
robust metal closer and door seal for dust protection and noise reduction, earthing pin.
Brief description: Piston pump system for spraying the smallest quantities of liquid.
Main application range: External MQL in all metal-cutting operations. Pinpoint or small area lubrication
in chipless forming operations. Application of mould release and anti-corrosion
agents or other spray-on substances.
Operating principle: The liquid flows from the reservoir into a piston pump. This
pushes an exact quantity of the lubricant into the internal feed
tube. Separately supplied compressed air splits the medium
at the nozzle tip and sprays it.
Adjustability: Swept volume of the pump (manual)
Clock frequency of the pump (manual)
Quantity of spray air (manual)
Spray air pressure (manual)
Switch on/ off via actuation control
device/drive (electric, pneumatic or manual)
?
?
?
Technical Data:
Operating pressure bar 4 - 8
Liquid throughput ml/h per nozzle 0 - 150 1)
Typical consumption ml/h per nozzle 10 - 20 1)
Lubricoolant Lubrimax? and others
Recommended viscosity mm2/s (at40°C) 1 - 100
1) depending on application, medium used, viscosity and temperature
?
?
?
Fig.: Pump module L60
Fig.: Lubrimat? L60
Lubrimat? L60
Page 9
- Connections for feed tube with EASY-COAX? system (plug-in system for speedy, simple assembly,
disassembly and interchange, including EASY-COAX? twist-stop) on the left side of the housing.
- Component labelling in accordance with the designations in the pneumatic connection diagram.
- Numbering clips on every liquid conduit.
2. Reservoirs from 0.33 to 27 litres available:
- Housing assembly
- Reservoir 0.33 litre PA with screw cap, ventilation plug, drainage sieve.
- Reservoir 1.0-/2.0-/3.0-litre with plexiglass cylinder / NBR seals or glass
cylinder / FPM seals. With filler neck, screw plug, detachable sieve,
automatic ventilation, drainage sieve. Can be supplied with float switch
min or min+max (potential-free, either NC or NO).
- Reservoir 6.0-/10-/17-/27-litre aluminium. With filler neck, screw plug,
detachable sieve, automatic ventilation, drainage sieve stopcock and
fill level display. Combinated wall-housing bracket of sturdy aluminium
construction 40x40 with 4 mounting straps for wall installation.
Can be supplied with float switch min or min+max (potential-free,
either NC or NO).
Vol. weight (kg)
6.0 288 x 260 x 370 4.0
10 324 x 315 x 370 5.5
17 357 x 369 x 370 7.0
27 388 x 491 x 390 10.5
*) = Dimensions given are approximate, including wall bracket, stopcock and
filler neck; for the float valve min option: height +4, for the float valve
min+max option: height +70.
Fig.: Reservoir P2NC (2.0l)
Fig.: Reservoir A27AWNC
200x200x150 250x250x210 300x250x210
A6AWG 6.0 553 x 265 x 370 598 x 265 x 370 654 x 265 x 370
A10AWG 10 589 x 315 x 370 634 x 315 x 370 690 x 315 x 370
A17AWG 17 622 x 369 x 370 667 x 369 x 370 723 x 369 x 370
A27AWG 27 653 x 491 x 390 698 x 491 x 390 754 x 491 x 390
400x400x210
748 x 400 x 370
784 x 400 x 370
817 x 400 x 370
848 x 491 x 390
*) = Dimensions given are approximate in mm, excluding mounting straps, feed tubes or valve rocker; for the float
switch min option: height +4, for the float switch min+max option: height +70.
Dimensions depending on housing size (HxWxD)
Dimensions*: Reservoir with wall-housing bracket (incl. housing)
Fig.: Lubrimat
with reservoir
- Wall installation A6AWGNC
- Reservoir 6.0-/10-/17-/27-litre aluminium as discribed before. With wall
bracket of sturdy aluminium construction 40x40 with 4 mounting straps for wall installation.
Can be supplied with float switch min or min+max (potential-free, either NC or NO).
Dimensions * (HxBxT)
Type Vol.
type
A6AW
A10AW
A17AW
A27AW
Vol.
Page 10
Lubrimat? L60
- Stirrer (pneumatic) for aluminium reservoirs
- The aluminium reservoirs (6.0- to 27- litres) are available with a
pneumatic stirrer. So it will be possible to keep media in motion
that otherwise would separate out. The pneumatic drive is lasting
and reliable and offers outstanding safety advantages (especially
explosive protection). The rpm of the rotating piston air engine is
progressively adjustable and an impulse generator guarantees