            Pacific Seismic 地震傳感器
            發布者:廈門紀揚科技有限公司  發布時間:2020-07-27 16:11:35  訪問次數:126

            Model 510 Seismic Switch is the most cost-effective seismic switch on the market.  It’s also rugged and low maintenance.510型地震開關是市場上最具成本效益的地震開關。堅固耐用且維護成本低

            Model 510 has a NEMA-12 enclosure.  For outdoor applications, Model 510 should be installed within a secondary enclosure that's rated at least NEMA 4.
            The factory's warranty period for Model 510 is one year.  No calibration is necessary (or possible), which mean there’s no need to retain someone to do semiannual or annual calibration visits.
            To minimize the likelihood of nuisance trips, some end-users connect three Model 510's to a PLC in a 2-of-3 logic array.  The idea behind a 2-of-3 logic array is to mount each of the three seismic switches far enough apart from each other so that aseismic vibrations would affect only one of them at a time.  If all 3 were connected to the same PLC, a unit-specific alarm could be issued whenever any Model 510 is in its actuated position; but a control signal would be sent by the PLC to the application only when 2 or 3 of the #510's are in their actuated position simultaneously.  Most modern PLC's have 2-of-3 capability.
            Each Model 510 has two identical Honeywell #BA-2RV22-A2 Microswitches.  Because each microswitch is SPDT (single-pole, double-throw), Model 510 is considered to be a DPDT (double-pole, double-throw) switch.  You may use one dry relay contact (N.C. or N.O.) to seismically control devices, and the other dry relay contact (N.C. or N.O.) to send an actuation-alert signal.  You'll find wiring details on the attached Operations and Maintenance Guide (5-page pdf).
            Model 510 must be reset manually; it cannot be reset remotely.  Model 510 is rated for 20 A at 125 VAC or 230 VAC; and 10 A at 125 VAC "L".
            As part of UL's quality-control program, UL performs random quarterly inspections at the factory (PSP); also, PSP performs a full set of 20 shake-table tests for every hundredth seismic valve or seismic switch in its production line.

            510型具有NEMA-12外殼。對于室外應用,應將510型安裝在額定至少為NEMA 4的輔助機柜中。
            510型的工廠保修期為一年。無需進行校準(或可能進行校準),這意味著無需聘請某人進行半年度或年度校準訪問。
            為了最大程度地減少絆倒的可能性,一些最終用戶將3個510型連接到2到3邏輯陣列中的PLC。 2分3邏輯陣列背后的想法是將三個地震開關中的每一個安裝得彼此足夠遠,以使地震振動一次只影響其中一個。如果所有3個都連接到同一PLC,則任何510型在其啟動位置時都可能發出特定于單元的警報。但是只有當#510中的2個或3個同時處于其驅動位置時,PLC才會將控制信號發送給應用程序。大多數現代PLC具有2 of 3功能。
            每個510型都有兩個相同的Honeywell#BA-2RV22-A2微動開關。因為每個微動開關都是SPDT(單刀雙擲),所以510型被認為是DPDT(雙刀雙擲)開關。您可以使用一個干式繼電器觸點(N.C.或N.O.)來控制設備,而另一個干式繼電器觸點(N.C.或N.O.)來發送致動警報信號。您可以在隨附的《操作和維護指南》(5頁pdf)中找到接線詳細信息。
            510型必須手動復位。無法遠程重置。 510型在125 VAC或230 VAC下的額定電流為20 A; 125 VAC“ L”時為10A。
            作為UL質量控制計劃的一部分,UL在工廠(PSP)進行季度隨機檢查;此外,PSP對生產線中的每100個地震閥或地震開關執行全套20次振動臺測試