            霍尼韋爾氣體傳感器MIDAS-E-NH3
            發布者:無錫遠路貿易有限公司  發布時間:2021-02-19 13:29:20  訪問次數:708

            Midas Cartridge Detectable Gases
            Gas Name Chemical Formula Range Sensor Part Number
            Ammonia NH3 9-100 ppm MIDAS-E-NH3
            Arsine AsH3 18-200 ppb MIDAS-E-ASH
            Boron Trichloride BCl3 0.72-8 ppm MIDAS-E-HCL
            Boron Trifluoride BF3 0.72-8 ppm MIDAS-E-HFX
            Boron Trifluoride (Low Level) BF3 0.18-2 ppm MIDAS-E-HFL
            Bromine Br2 0.036-0.4 ppm MIDAS-E-BR2
            Carbon Dioxide CO2 0.15-2.0% MIDAS-E-CO2
            Carbon Monoxide CO 9-100 ppm MIDAS-E-COX
            Chlorine Cl2 0.18-2 ppm MIDAS-E-HAL
            Chlorine Dioxide ClO2 0.036-0.4 ppm MIDAS-E-BR2
            Diborane B2
            H6 36-400 ppb MIDAS-E-B2H
            Dichlorosilane H2
            Cl2
            Si 0.72-8 ppm MIDAS-E-HCL
            Difluoromethane** CH2
            F2 16-240 ppm MIDAS-E-XCF
            Disilane Si2
            H6 1.8-20 ppm MIDAS-E-SHX
            Fluorine F2 0.36-4 ppm MIDAS-E-HAL
            Germane GeH4 70-800 ppb MIDAS-E-ASH
            Hexafluorobutadiene** C4
            F6 3-40 ppm MIDAS-E-CFX
            Hydrogen (%LEL) H2 6.5-100% LEL MIDAS-E-LEL*
            Hydrogen (ppm) H2 90-1000 ppm MIDAS-E-H2X
            Hydrogen Bromide HBr 0.72-8 ppm MIDAS-E-HCL
            Hydrogen Chloride HCl 0.72-8 ppm MIDAS-E-HCL
            Hydrogen Cyanide HCN 1.8-20 ppm MIDAS-E-HCN
            Hydrogen Fluoride HF 1.05-12 ppm MIDAS-E-HFX
            Hydrogen Fluoride (Low Level) HFL 0.18-2 ppm MIDAS-E-HFL
            Hydrogen Sulfide H2
            S 3.6-40 ppm MIDAS-E-H2S
            Methane (%LEL) CH4 6.5-100% LEL MIDAS-E-LEL*
            Methyl Fluoride** CH3
            F 8-120 ppm MIDAS-E-XHF
            Nitric Oxide NO 9-100 ppm MIDAS-E-NOX
            Nitrogen Dioxide NO2 1.05-12 ppm MIDAS-E-NO2
            Nitrogen Trifluoride** NF3 3.6-40 ppm MIDAS-E-HFX for 00P, XHF for NP1
            Octofluorocyclopentene** C5
            F8 3-40 ppm MIDAS-E-XCF
            Oxygen O2 0.2-25% v/v MIDAS-E-O2X
            Ozone O3 0.065-0.7 ppm MIDAS-E-O3H
            Ozone (Low Level) O3 0.036-0.4 ppm MIDAS-E-O3X
            Phosphine PH3 110-1200 ppb MIDAS-E-PH3
            Silane SiH4 1.8-20 ppm MIDAS-E-SHX
            Silane (Low Level) SiH4 0.18-2 ppm MIDAS-E-SHL
            Sulfur Dioxide SO2 0.7-8 ppm MIDAS-E-SO2
            Tetra Ethyl Ortho Silicate TEOS 3.6-40 ppm MIDAS-E-TEO
            Tungsten Hexafluoride WF6 1.05-12 ppm MIDAS-E-HFX
            Tungsten Hexafluoride (Low Level) WF6 0.18-2 ppm MIDAS-E-HFL

            Midas H2氫氣氣體探測傳感器MIDAS-S-H2X MIDAS-E-H2X

            Hydrogen ppm (H2)
            MIDAS-S-H2X
            MIDAS-E-H2X
            Midas? sensor cartridges are intended
            for use only with Honeywell Analytics’
            Midas? Gas Detector System. Please
            refer to the Midas? Technical Manual
            for further details.
            Technical Data
            Gas Measured Hydrogen (H2)
            Cartridge Part Number MIDAS-S-H2X 1 year standard warranty
            MIDAS-E-H2X 2 year extended warranty
            Sensor Technology 3 electrode electrochemical cell
            Measuring range (ppm) H2 0 – 1000 ppm
            Minimum Alarm 1 Set Point 120 ppm
            Lower Detectable Limit (LDL) 90 ppm
            Repeatability < ? 5 % of measured value
            Linearity < ? 5 % of measured value
            Response Time t62.5 < 50 seconds
            Sensor Cartridge Life Expectancy ≥ 24 months under typical application conditions
            Operating Temperature 0? to 40?C (32? to 104?F)
            Effect of Temperature < ? 0.17 ppm / ?C (0? to 20?C )
            Zero < ? 0.07 ppm / ?C (20? to 40?C )
            Sensitivity < ? 3 % of measured value / ?C
            Operating Humidity (continuous) 10 – 90 % rH
            Effect of Humidity
            Zero No Effect
            Sensitivity No Effect
            Operating Pressure 90 – 110 kPa
            Effect of bbbbbbbb No effect in typical application
            Long Term Drift
            Zero No Drift
            Sensitivity < ? 10 % of measured value / 6 month
            Calibration Gas Hydrogen (H2)
            Challenge Gas (Bump Test) Hydrogen (H2)
            Warm Up time < 10 minutes
            Storage Temperature 5? to 25?C ( 41? to 77?F)
            The sensor data listed is based on ideal test environment; observed performance may vary based on the actual monitoring system and the sampling conditions employed
            Gas / Vapor Chemical Formula Concentration applied (ppm) Reading (ppm H2)
            Ammonia NH3 100 0
            Arsine AsH3 0.2 0
            Carbon Dioxide CO2 1000 0
            Carbon Monoxide CO 100 150
            Chlorine Cl2 1 0
            Chlorine Dioxide ClO2 1 0
            Hydrogen Cyanide HCN 20 0
            Hydrogen Sulfide H2S 20 4
            Iso Propanol C3H7OH 1100 Yes
            Methane CH4 1% 0
            Nitrogen Dioxide NO2 10 -40
            Ozone O3 0.25 0
            Sulfur Dioxide SO2 5 0
            MDA Scientific has developed a sophisticated range of highly sensitive gas detection equipment, designed to perform in ways that define new gas detection performance levels providing total solutions to protect people, improve production efficiency and reduce costs.

            Midas? is a registered trademark of Honeywell Analytics.
            As with all electrochemical sensor cells, dramatic output changes in reported concentrations can be
            expected under rapidly changing environmental conditions. Please ensure sensors are located in areas not
            prone to sudden changes in humidity and temperature.
            Actual readings may be affected by flow rates (although Midas? automatically controls flow rate within
            specified ranges) and absorption on tubing and other gas path surfaces.
            All sensors are shipped pre-calibrated to traceable national standards. Dependent on actual operating
            conditions and overall exposure to gases, each sensor may not require in field calibration for up to 24
            months subject to any requirements to calibrate from local regulations or site practices.
            Calibration and challenge gases should be from a certified and reliable source.
            Cross Sensitivities
            Each Midas? sensor is potentially cross sensitive to other gases and this may cause a gas reading when
            exposed to other gases than those originally designated. The table below presents typical readings that
            will be observed when a new sensor cartridge is exposed to the cross sensitive gas (or a mixture of gases
            containing the cross sensitive species).